亚洲AV成人片无码网站玉蒲团,男人10处有痣是富贵痣,AV亚洲欧洲日产国码无码苍井空,日韩午夜欧美精品一二三四区

官方微信|手機版

產品展廳

產品求購企業資訊會展

發布詢價單

化工儀器網>產品展廳>物理特性分析儀器>表面/界面性能測定儀>開爾文探針系統> 專業銷售 英國Uniscan Instruments SKP370 ...

分享
舉報 評價

專業銷售 英國Uniscan Instruments SKP370 掃描開爾文探針系統

具體成交價以合同協議為準

聯系方式:錢經理查看聯系方式

聯系我們時請說明是化工儀器網上看到的信息,謝謝!


北京恒遠安諾科技有限公司,十多年來專注于儀器儀表及各種工業品進出口.

進口儀器儀表

SKP370

Scanning Kelvin Probe System

The Scanning Kelvin Probe (SKP) is a non-contact, non-destructive instrument designed to measure the surface work function difference between conducting, coated, or semi-conducting materials and a metallic probe. The technique operates using a vibrating capacitance probe, and through a swept backing potential, the work function difference is measured between the scanning probe reference tip and sample surface. The work function can be directly correlated to the surface condition. A unique aspect of the SKP is its ability to make measurements in a humid or gaseous environment.  Applications include: -

 
scanning kelvin probe 
Figure 1
  • Filiform corrosion studies
  • Transport process of hydrated ions
  • Study of fuel cell catalysts
  • Forensic detection of fingerprints
  • Charaterisation of photovoltaic materials
  • Femi-level mapping

The principle of operation of the Kelvin Probe is illustrated in Figure 1.

The figure represents three energy level diagrams depicting two metals having a constant separation, work functions and Fermi levels of (φ1, E1) and (φ2, E2), respectively.

The first diagram shows the metals with no electrical contact and differing Fermi levels. When electrical contact is made (middle diagram) the flow of charge allows the Fermi levels to equalize and gives rise to a surface charge.

 

The potential difference, VC, is related to the difference in work function:

-eVC = φ1 - φ2 (1) where e is the electron charge.

The inclusion of an external backing potential, VB (final diagram), allows for a nulling of the surface charge at a unique point where VB = - VC. This point represents the work function difference between the two materials.  Work function can then be used to determine the corrosion potential (Ecorr) at a specific point using the relationship:

Ecorr = Constant + (φ1 - φ2) (2) where (φ1 - φ2) is the measured work function between the probe and the sample. 

 
filiform corrosion 
Figure 2

The constant can be determined by measuring the corrosion potential using a conventional reference electrode in an electrolyte. Once the constant is known for a particular sample, Ecorr can be calculated directly from the SKP data without an electrolyte.

 

Figure 2 shows the Scanning Kelvin Probe Measurement of filiform corrosion on Aluminium

 
 

Figure 3

Figure 3 shows a surface map of the Scanning Kelvin Probe signal recorded over the heat affected zone of welded material.

 
 

Figure 4


 

Figure 4 shows a surface map of the Scanning Kelvin Probe signal recorded over a printed circuit board.

如果您對本品感興趣請與我公司
北京東方安諾生化科技有限公司
:    -8007


: www.annovatech.com
: caoye513



化工儀器網

采購商登錄
記住賬號    找回密碼
沒有賬號?免費注冊

提示

×

*您想獲取產品的資料:

以上可多選,勾選其他,可自行輸入要求

個人信息:

溫馨提示

該企業已關閉在線交流功能