KIMRAY電液動執行器美國原產經銷專業經銷銷售進口美國KIMRAY 燃氣減壓閥;凱姆雷減壓閥詳細參數如下:適用于天然氣系統區域控制及工業、公共用戶的調壓器
調壓精確、關閉靈敏、壓力設定簡單
大皮膜執行機構組合指揮器使得調壓器動作靈敏,反應速度快
一體化的過壓、失壓切斷裝置,確保用戶安全
可在線維修可作監控連接,保證安全
流通能力大,結構緊湊;密封嚴密,無氣體滲漏
安裝省力,經濟實惠
進口壓力范圍:200kg
出口壓力范圍:15kg
流量:1500m3/h
精度:±2.5%
連接方式:1"
材料:鑄鐵,韌性鑄鐵或WCB 鋼制閥體
溫度:-29°~66℃
選項:可在指揮器前配置過濾器
內置超高壓/超低壓切斷裝置
大皮膜執行機構組合指揮器使得調壓器動作靈敏,反應速度快
多種壓力信號選取方式
可用于天然氣、人工煤氣、液化石油氣、空氣等多種氣體
美國*KIMRAY高壓調節器/凱姆鐳電液動執行器的詳細資料: |
美國*KIMRAY高壓調節器/凱姆鐳電液動執行器 電液動執行器Electro Hydraulic actuatorINTRODUCTION As requirements for low emission processes make your job more difficult, Kimray has a solution. Using our rich experience in the oil and gas industry, we have developed the Kimray Electro-Hydraulic Actuator. Using a high efficiency hydraulic pump, you can now actuate your valves with no emissions. And with a small solar panel, this solution becomes self contained and energy independent. This can be used with any size Kimray topworks, or and spring return topworks requiring 30 psi to actuate.
美國*KIMRAY高壓調節器/凱姆鐳電液動執行器 OPERATIN G PRINCIPLE For all versions of the EHA, hydraulic oil is shuttled from the area on top of the diaphragm to the area underneath the diaphragm through a manifold. For a Pressure Opening (PO) valve the volume on the top of the diaphragm acts as a storage space for hydraulic oil at atmospheric pressure. The volume underneath the diaphragm is pressurized to actuate the valve open. An oil reservoir is attached to the top of the valve actuator to allow for hydraulic oil input and visual measurement of the hydraulic oil level. The EHA can be used with either a pressure to open valve or a pressure to close valve. When a signal is received through the control circuit to open a PO valve, the pump is activated and begins to move and pressurize the hydraulic oil out of the top of the diaphragm space and into the volume underneath the diaphragm. The valve actuator begins to open the valve. For the Discrete (ON/OFF) version, the pump continues with pressure being monitored by the pressure transducer until the maximum set point is reached. At that point, the pump is deactivated and the valve remains open. The Discrete version does not have position feedback. Two discrete inputs (such as a GEN II electronic level controller) are monitored for operation. The first discrete input notifies the controller to begin opening the valve by changing from an open contact to a closed contact. The second discrete input notifies the controller to begin closing the valve by changing from an open to a closed contact.
Specifications Pressure: 30 PSI Current: | Open | Hold Open | Closing | Hold Close | 12 Fail safe | 3A | 2.6A | 1.4A | 1.2A | 12 fail in place | 0.3mA | 10mA | 0.2mA | 10mA | 24 Fail safe | 10mA | 0.3mA | 10mA | 0.2mA | 24 fail in place | 10mA | 10mA | 10mA | 10mA |
Voltage : 12 VDC (11.0-14.0 VDC) 24 VDC (22.0-26.0 VDC) MODBUS input (TDA-, TDB+): RS-485 Temperature: -40°F to 140 Hydraulic Oil: Kimzoil #6927 Actuation Times:
| 1" HPMV | 2" HPMV | Full Open | 7s | 25s | Full Closed | 2s | 15s |
|