亚洲AV成人片无码网站玉蒲团,男人10处有痣是富贵痣,AV亚洲欧洲日产国码无码苍井空,日韩午夜欧美精品一二三四区

蘇州東偉元電子有限公司
中級(jí)會(huì)員 | 第12年

13913158248

當(dāng)前位置:蘇州東偉元電子有限公司>>中國(guó)臺(tái)灣儀鼎PICOTEST>>PICOTEST測(cè)試訊號(hào)轉(zhuǎn)換器>> INJB02PICOTEST儀鼎儀器專業(yè)測(cè)試訊號(hào)轉(zhuǎn)換器

PICOTEST儀鼎儀器專業(yè)測(cè)試訊號(hào)轉(zhuǎn)換器

參  考  價(jià)面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)

產(chǎn)品型號(hào)INJB02

品       牌PICOTEST/中國(guó)臺(tái)灣儀鼎

廠商性質(zhì)代理商

所  在  地蘇州市

更新時(shí)間:2024-11-03 14:24:04瀏覽次數(shù):2491次

聯(lián)系我時(shí),請(qǐng)告知來(lái)自 化工儀器網(wǎng)
PICOTEST儀鼎儀器專業(yè)測(cè)試訊號(hào)轉(zhuǎn)換器專業(yè)代理銷售現(xiàn)貨供應(yīng)INJB01,INJB02,INGB03,J2100A.J2101A,J2102A,J2110A,J2111A,J2112A,J2120A,J2130A,J2140A,J2160A,J2180A,J2180A-20,J2190A

PICOTEST儀鼎儀器專業(yè)測(cè)試訊號(hào)轉(zhuǎn)換器

 

What's included:
J2100A Injection Transformer 1Hz - 5MHz
J2101A Injection Transformer 10Hz - 45MHz
J2110A Solid State Injector
J2120A Line Injector
J2130A DC Bias Injector
J2111A Current Injector 
J2170A High PSRR Power Adapter (Shipped Separay)
User manual

PICOTEST儀鼎儀器專業(yè)測(cè)試訊號(hào)轉(zhuǎn)換器

What's included:
J2110A Solid State Injector
J2111A Current Injector
J2120A Line Injector
J2130A DC Bias Injector
J2140A Attenuator 
J2170A High PSRR Power Adapter
User manual

What's included:
J2111A Current Injector
J2101A Injection Transformer 10Hz - 45MHz
J2120A Line Injector
J2140A Attenuator 
J2170A High PSRR Power Adapter
User manual

J2100A Injection Transformer 1Hz~5MHz 

 
 
J2100A測(cè)試訊號(hào)轉(zhuǎn)換器
 
 
iconLow band corner frequency 達(dá)1Hz,可支援 功率因數(shù)控制器(PFC)之穩(wěn)定性測(cè)試
icon5MHz帶寬足以量測(cè)大多數(shù)電源和穩(wěn)壓器
icon超高頻寬,可達(dá)23 Octave
icon優(yōu)異精確的低失真表現(xiàn)
icon5Ω終端,對(duì)待測(cè)電路的影響降至zui小
icon包括衰減功能來(lái)確保小信號(hào)的測(cè)量正確性
icon詳細(xì)規(guī)格
 
Product Information

The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.

The usable bandwidth of an injection transformer is generally significantly greater than the 3dB frequency limits. This is because the transformer itself is outside of the measurement, leading many to incorrectly believe that the transformer is a non-critical element.

The bandwidth of the transformer is strongly related to the terminating impedance. The most network analyzers provide a 50 Ohm oscillator source impedance. Assuming this impedance the optimal termination resistor is 5 Ohms. This significantly attenuates the injection signal, which is generally beneficial, as a common error in Bode measurements is using a signal which is too large, and therefore not a small signal measurement. An added benefit of this low value is that it can generally be left in circuit at all times, simplifying the connection to the network analyzer without appreciably impacting the output voltage of the circuit being tested.

 
Detailed Specifications:
 
Performance at -10dBm input level
CharacteristicRating
DCR 
Ratio1:1
Termination Impedance5 Ohms
Nominal 3dB Bandwidth1Hz ~ 5MHz
Isolation Voltage600V
Isolation Capacitance390pF@1KHz
DC Current10mA
Temperature Range0 ~ 50°C
Maximum Altitude6000 Ft

 J2100A測(cè)試訊號(hào)轉(zhuǎn)換器

J2100A 1 hz - 5 mhz
J2101A  10 hz - 45 mhz
J2110A
J2120A
J2130A

J2140A

J2160A

J2180A

J2180A

J2190A

 

會(huì)員登錄

×

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
撥打電話
在線留言